HPE Advanced Storage Architect (HPE7-J01) Certification Sample Questions
Getting knowledge of the Hewlett Packard Enterprise HPE7-J01 exam structure and question format is vital in preparing for the Advanced HPE Storage Architect certification exam. Our HPE Advanced Storage Architect sample questions offer you information regarding the question types and level of difficulty you will face in the real exam. The benefit of using these Hewlett Packard Enterprise HPE7-J01 sample questions is that you will get to check your preparation level or enhance your knowledge by learning the unknown questions. You will also get a clear idea of the exam environment and exam pattern you will face in the actual exam with the Advanced HPE Storage Architect Sample Practice Test. Therefore, solve the HPE MASE-StorArcSol sample questions to stay one step forward in grabbing the HPE Master ASE - Storage Architect credential.
These Hewlett Packard Enterprise HPE7-J01 sample questions are simple and basic questions similar to the actual HPE Advanced Storage Architect questions. If you want to evaluate your preparation level, we suggest taking our Advanced HPE Storage Architect Premium Practice Test. You might face difficulties while solving the real-exam-like questions. But, you can work hard and build your confidence on the syllabus topics through unlimited practice attempts.
Hewlett Packard Enterprise HPE7-J01 Sample Questions:
01. An insurer replicates its production databases to HPE arrays at a DR site, where the arrays sit mostly idle. Developers wait days for refreshed test copies, because the DBAs will not run copy jobs against production in business hours. Which opportunity should the architect raise?
a) Space-efficient clones of the DR replicas, presented to test hosts at the DR site
b) A third array at headquarters for testing, loaded every night from production backups
c) Faster production media, so copy jobs finish quickly in business hours
d) Test databases moved onto production, with QoS limits to protect the live workload
02. After a planned power-down for electrical work, a manufacturer's HPE arrays, which use self-encrypting drives, powered back on but could not unlock their drives for six hours. Policy requires keys to be held outside the arrays. The only key manager was a virtual machine stored on those same arrays, so it could not start until the drives were unlocked.
Which TWO changes should the architect advocate?
(Select TWO.)
a) Store the key manager VM on an unencrypted volume of the same arrays
b) Run the key managers on infrastructure outside the arrays whose keys they hold
c) Cluster the key managers, with at least one member in a separate failure domain
d) Snapshot the key manager VM on the same arrays before each power-down
03. In a new SAN design, all 40 hosts are zoned to the same two front-end ports, one on each controller of an HPE Alletra array with several more front-end ports per controller. Peak testing shows those two ports saturated, the other ports idle, and latency rising.
What should the architect change in the design?
a) Raise every host's HBA queue depth, so each host keeps more I/O in flight
b) Zone each host to a single port, so each saturated port carries half of the hosts
c) Add a second array, so half of the hosts move to its front-end ports
d) Spread the hosts' zoning across the front-end ports of both controllers
04. A post-incident review covers a week of intermittent latency spikes that hit every host on fabric A at the same moments, and no host on fabric B. Array utilization stayed low throughout. Switch statistics show buffer-credit starvation on fabric A's inter-switch links, traced to one backup server's HBA port that was slow to return credits.
Which TWO changes should the architect advocate?
(Select TWO.)
a) Repair or isolate the slow-drain device that is starving the shared links of credits
b) Add controller nodes and front-end ports to the array, so it absorbs the spikes on fabric A
c) Move every host to fabric B until fabric A's switches are replaced
d) Enable port monitoring and alerting that detects slow-drain behavior across the fabrics
05. Asynchronous replication between two offices shares a WAN link with their voice and VDI traffic. When change rates spike, call quality drops; when users are busy, replication falls behind its RPO. Which design change should the architect make?
a) Lengthen the replication interval, so cycles run less often and voice has more room
b) A guaranteed bandwidth share for replication through QoS, or a dedicated link
c) Compress the voice traffic, so replication can use whatever bandwidth is left
d) Switch to synchronous replication, so changes are sent as they happen rather than in bursts
06. An insurer must encrypt all data at rest on the media of its new HPE all-flash array to pass an audit. The array was sized assuming the claims databases would reduce as well as they do today. The DBA team proposes turning on the database engine's own transparent encryption for every database.
What should the architect advise?
a) Enable both database and array encryption, so the audit sees two layers and the sizing stays as it is
b) Defer encryption until after go-live, so the data-reduction ratio can be measured first
c) Enable database encryption as proposed, relying on the array to still deduplicate and compress the pages
d) Use the array's at-rest encryption, applied after data reduction, so the sizing holds
07. A retailer will place HPE MSA arrays in 60 stores that have no IT staff, and store managers are not permitted to open equipment. The draft bill of materials relies on replacement parts being shipped to each store for local staff to fit. What should the architect add to the proposal?
a) An HPE support service that includes on-site part replacement by an HPE engineer
b) A longer warranty term, keeping the same shipped-parts arrangement
c) Spare drives and controllers held in every store, so managers can fit them when alerted
d) Remote management from headquarters, so administrators can replace parts without traveling
08. Two data centers 20 km apart will replicate a trading database synchronously. Its daily average write rate is modest, but for about 30 minutes after market open it writes in bursts several times that rate. The draft design sizes the inter-site link from the daily average.
Which TWO statements should the architect raise about the link sizing?
(Select TWO.)
a) An undersized link affects only the RPO, so response times stay the same
b) Every write waits for the remote commit, so the link must carry the peak write rate
c) When bursts exceed the link, writes queue and the database sees longer response times
d) Synchronous replication batches writes and sends them later, so the daily average is the right basis
09. Before a quarterly business review, a partner architect looks at HPE InfoSight data for a customer's installed HPE Alletra 6000 arrays. The telemetry forecasts that two arrays will reach their capacity thresholds within five months. The customer has not mentioned any storage need.
How should the architect use this finding?
a) Propose a full replacement of the arrays, reading the forecast as an end-of-life signal
b) Raise the forecast at the review and propose an expansion sized from the telemetry trend
c) Wait until the customer raises a capacity request, so the opportunity stays customer-led
d) Raise the arrays' capacity alert thresholds, so the forecast no longer flags them
10. A design review of a hospital storage design that must have no single point of failure finds that every array, switch and server has redundant power supplies. In the rack plan, however, every power supply is cabled to the same power distribution unit (PDU), which is fed from a single UPS.
Which TWO changes should the architect require?
(Select TWO.)
a) Add a third power supply to each component, cabled to the existing distribution unit
b) Move the fabric switches to a different rack, keeping them on the same PDU
c) Feed the two PDUs from independent power sources, such as separate UPS systems
d) Cable each component's redundant power supplies to two different PDUs
Answers:
|
Question: 01 Answer: a |
Question: 02 Answer: b, c |
Question: 03 Answer: d |
Question: 04 Answer: a, d |
Question: 05 Answer: b |
|
Question: 06 Answer: d |
Question: 07 Answer: a |
Question: 08 Answer: b, c |
Question: 09 Answer: b |
Question: 10 Answer: c, d |
Note: For any error in Advanced HPE Storage Architect (HPE7-J01) certification exam sample questions, please update us by writing an email on feedback@certfun.com.
- HPE7-J01 Questions |
- HPE7-J01 Quiz |
- HPE7-J01 |
- HPE Advanced Storage Architect Certification |
- Hewlett Packard Enterprise HPE7-J01 Question Bank |
- MASE-StorArcSol Mock Exam |
- MASE-StorArcSol |
- HPE MASE-StorArcSol Certification |
- Advanced Storage Architect Sample Questions |
- Hewlett Packard Enterprise HPE7-J01 Practice Test Free |
- MASE-StorArcSol Certification Sample Questions