HPE Advanced Edge-to-Cloud Solutions (HPE7-V01) Certification Sample Questions

Hewlett Packard Enterprise HPE7-V01 VCE, Advanced Edge-to-Cloud Solutions Dumps, HPE7-V01 PDF, HPE7-V01 Dumps, Advanced Edge-to-Cloud Solutions VCE, HPE MASE-EdgCldAr PDFGetting knowledge of the Hewlett Packard Enterprise HPE7-V01 exam structure and question format is vital in preparing for the Advanced HPE Edge-to-Cloud Solutions certification exam. Our HPE Advanced Edge-to-Cloud Solutions sample questions offer you information regarding the question types and level of difficulty you will face in the real exam. The benefit of using these Hewlett Packard Enterprise HPE7-V01 sample questions is that you will get to check your preparation level or enhance your knowledge by learning the unknown questions. You will also get a clear idea of the exam environment and exam pattern you will face in the actual exam with the Advanced HPE Edge-to-Cloud Solutions Sample Practice Test. Therefore, solve the HPE MASE-EdgCldAr sample questions to stay one step forward in grabbing the HPE Master ASE - Edge-to-Cloud Architect credential.

These Hewlett Packard Enterprise HPE7-V01 sample questions are simple and basic questions similar to the actual HPE Advanced Edge-to-Cloud Solutions questions. If you want to evaluate your preparation level, we suggest taking our Advanced HPE Edge-to-Cloud Solutions Premium Practice Test. You might face difficulties while solving the real-exam-like questions. But, you can work hard and build your confidence on the syllabus topics through unlimited practice attempts.

Hewlett Packard Enterprise HPE7-V01 Sample Questions:

01. A logistics company runs its warehouse management system as a single, non-clustered application instance on servers whose support ends next quarter. The business accepts at most 30 minutes of downtime for the move to new HPE ProLiant servers. If the new platform misbehaves, operations must be able to return to the old platform within the same 30 minutes.
Which migration approach best meets these requirements?
a)
Move the application to a public cloud first, re-platform it there, and bring it onto the new ProLiant servers later
b) Build the new servers alongside the old ones, replicate data ahead, and keep the old system as fallback
c) Upgrade the existing servers in place over a weekend, re-imaging them if problems appear
d) Perform a rolling upgrade one node at a time so that the application stays online throughout
 
02. A food manufacturer is consolidating three small virtualization clusters into one 16-host HPE Synergy cluster. Two of the workloads are database VMs. The customer confirms that its database vendor licenses the physical cores of each host on which a database VM is able to run, and the current database clusters have four hosts in total.
Which change to the proposed design best protects the customer's licensing position?
a)
 
Confine the database VMs to a mandatory host group or a separate small cluster
b) Apply anti-affinity so the two database VMs run on different hosts
c) Spread the database VMs across all 16 hosts so load stays balanced
d) Reduce the vCPU count of each database VM so that fewer licensed cores are consumed
 
03. A university system's HPE GreenLake proposal for virtualization and backup was sized and agreed in principle. Before sign-off, the university absorbed a smaller college, adding about 30% more virtual machines, and its auditors added a requirement that backup copies be immutable.
Which two actions should the architect take before the proposal is signed?
(Select two.)
a)
Sign now and add the college's workloads later by change order
b) Raise the reserved commitment now to cover the college's anticipated consumption growth
c) Scale the existing buffer by the acquired college's VM count and leave the other sizing as is
d) Collect metrics from the acquired college's workloads and re-run the capacity sizing
e) Revise the data protection design so backup copies meet the immutability requirement
 
04. A hotel group's CFO is reviewing an HPE GreenLake proposal and has told the board the company will "only pay for what we use." The proposal includes a reserved capacity commitment billed every month, with usage above the reserve billed as metered consumption. Occupancy, and therefore demand, could fall sharply in a downturn.
What should the architect present to the CFO?
a)
Average expected monthly charges over the term, based on the current occupancy forecast
b) The full metered rate card, so the board can estimate charges for any level of usage it expects
c) Monthly cash flow at forecast and downturn demand, with the reserve as a fixed minimum
d) A comparison of total GreenLake payments, over the term, with the purchase price of equivalent hardware
 
05. A media archive company is moving 180 TB of active project data from an old array to a new HPE Alletra Storage MP array in another building. Measured sustained throughput on the migration link is 2 Gb/s. The business has approved a 48-hour cutover window over a weekend, and all 180 TB is in daily use.
What does comparing the transfer time with the cutover window show?
a)
Doubling the link throughput would fit the full copy into the 48-hour window
b) The full copy fits in the window, since 2 Gb/s moves 180 TB in about 25 hours
c) 
Extending the window to 72 hours would let the full copy complete during the cutover itself
d) The bulk copy must run before the window, leaving only changed data for the cutover
 
06. A claims-processing company is reviewing a traditional design: a six-node HPE ProLiant virtualization cluster labeled N+1. Collected metrics show cluster memory use averages 55% but reaches 88% during the month-end claims run. The company requires full month-end performance even if one host fails.
What should the architect conclude?
a)
The design is sound, because six hosts leave one spare above the five that are needed
b) The design falls short until each host has redundant power supplies and network adapters
c) The design is sound, because 55% average use leaves room for a failed host's workload
d) Five hosts cannot carry the month-end memory peak, so capacity must grow
 
07. A video streaming company moved its recommendation analytics to a public cloud three years ago. The CFO now proposes moving it to HPE GreenLake in the company's colocation facility, citing a monthly compute bill that is double the GreenLake quote. The platform holds 2 PB in cloud object storage and uses the provider's managed data warehouse service.
Which cost comparison should the architect present before a decision is made?
a)
Three years of cloud spend to date against the GreenLake quote over a matching term
b) Full run cost plus one-time egress and managed-service re-platforming
c) Monthly cloud compute and storage charges against the monthly GreenLake charge
d) Current cloud storage charges against list prices for equivalent on-premises arrays
 
08. A freight logistics company is buying an HPE ProLiant and HPE Alletra platform together with third-party backup software and a third-party database monitoring product that HPE has validated with the solution. Procurement wants to avoid separate contracts with each software vendor, and operations wants to stop being passed between vendors when something fails.
Which two benefits does HPE Complete provide here?
(Select two.)
a)
Integration services that customize the third-party software for the company
b) HPE as the first point of contact for support on the full solution
c) One HPE purchase covering the validated third-party products
d) HPE staff operating the third-party products day to day
e) Consumption billing for the third-party licenses through HPE GreenLake
 
09. A software company will host its HPE GreenLake for Private Cloud deployment in a colocation facility. The colocation contract provides 8 kW of power and matching cooling per rack, and the cage's total power allocation exceeds the deployment's total draw. The proposed rack layout places dense compute nodes so that two racks draw about 14 kW each.
What should the architect do before the order is finalized?
a)
Redistribute equipment or contract denser racks so each rack stays within its limit
b) Proceed, because the cage's total power allocation covers the deployment's total draw
c) Add redundant power distribution units and transfer switches to the two dense racks
d) Ask the colocation provider to lower cooling setpoints around the dense racks
 
10. A credit union has finished migrating to a new HPE Alletra Storage MP array and plans to remove its three old arrays from the data center as a trade-in to its reseller. Its regulator requires documented evidence that member data on retired storage media has been rendered unrecoverable.
Which decommissioning step should the architect include in the plan?
a)
Delete all volumes, reinitialize each array, and then let the reseller collect them
b) Transfer the arrays to the reseller and rely on its standard data-handling terms
c) Certified sanitization of each drive evidenced device by device before removal
d) Record the arrays' serial numbers in the asset register before collection

Answers:

Question: 01
Answer: b
Question: 02
Answer: a
Question: 03
Answer: d, e
Question: 04
Answer: c
Question: 05
Answer: d
Question: 06
Answer: d
Question: 07
Answer: b
Question: 08
Answer: b, c
Question: 09
Answer: a
Question: 10
Answer: c

Note: For any error in Advanced HPE Edge-to-Cloud Solutions (HPE7-V01) certification exam sample questions, please update us by writing an email on feedback@certfun.com.

Rating: 4.8 / 5 (38 votes)